單項(xiàng)選擇題Short cycling of a refrigeration compressor refers to ().

A.frequently grounding out
B.frequently starting and stopping
C.running too fast
D.running too slow


您可能感興趣的試卷

你可能感興趣的試題

1.單項(xiàng)選擇題When a flash-type evaporator is to be secured for an extended period of time, the entire unit should be drained, cleaned, and ().

A.completely filled with saltwater
B.filled with de-scaling compound
C.tightly closed to exclude air
D.vented to the atmosphere

2.單項(xiàng)選擇題Condensate must be drained periodically from the air compressor receivers to prevent ().

A.second stage cylinder lockup
B.oil sump contamination
C.faulty operation of pneumatic valves
D.corrosion of air receiver baffles

3.單項(xiàng)選擇題Overheating of a hydraulic system may be a result of ().

A.changing pump discharge pressure in response to normal load variations
B.a high oil level
C.incorrect fluid viscosity
D.continued slow re-circulation of the oil

4.單項(xiàng)選擇題The purpose of the low pressure cut-out switch is to ().

A.maintain liquid refrigerant at the suction of the compressor
B.maintain a preset suction pressure to the compressor
C.start and stop the compressor at preset operating pressures
D.operate at minimum efficiency

5.單項(xiàng)選擇題The process of boiling seawater in order to separate it into freshwater vapor and brine is usually defined as ().

A.dehydration
B.condensation
C.evaporation
D.dissolution

最新試題

An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().

題型:單項(xiàng)選擇題

Pitting in the suction areas of a centrifugal pump bronze impeller is usually caused by ().

題型:單項(xiàng)選擇題

The temperature differential occurring between the inlet temperature of the fluid to be cooled and the outlet temperature of the cooling medium in a shell-and-tube heat exchanger is greatest in which of the flow designs listed?()

題型:單項(xiàng)選擇題

The general purpose of a heat exchanger is to ().

題型:單項(xiàng)選擇題

If the suction pressure at the refrigeration compressor is below normal, the cause can be().

題型:單項(xiàng)選擇題

A pressure drop through the refrigerant liquid line may cause ().

題型:單項(xiàng)選擇題

The rate of heat transfer between the hot and cold fluids passing through a shell-and-tube type heat exchanger will ().

題型:單項(xiàng)選擇題

The amount of fluid friction or internal friction inherent in a mineral lubricating oil is reflected as a measure of its ().

題型:單項(xiàng)選擇題

If the viscosity of the liquid being transferred remains constant as the discharge pressure increases, the rotary pump ().

題型:單項(xiàng)選擇題

Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()