A.at the compressor discharge
B.at the compressor suction
C.in the expansion valve
D.in the receiver
您可能感興趣的試卷
你可能感興趣的試題
A.Pressure-reducing valve
B.Unloading valve
C.Counterbalance valve
D.Pressure-relief valve
A.motor overload would open
B.relief valve would open
C.pump would eventually overheat
D.motor would overheat
A.Compound gage
B.Bonrdon tube
C.Manometer
D.Deadweight gage
A.cavitation
B.water hammer
C.fluid friction
D.steam knock
A.sub-cooled liquid
B.high temperature liquid
C.oil saturated liquid
D.superheated vapor
最新試題
Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()
If you are given the job of adding hydraulic fluid to a mooring winch, and are not certain as to the type of fluid to use, you should ().
Pitting in the suction areas of a centrifugal pump bronze impeller is usually caused by ().
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()
The control mode in which the final control element is moved from one of two flexed positions to the other is known as ().
Low compressor head pressure in a refrigeration system can be caused by().
A salinity indicator is used to determine the ().
An internal bypass is provided on some hydraulic system suction strainers to help reduce the possibility of ().
The rate of heat transfer between the hot and cold fluids passing through a shell-and-tube type heat exchanger will ().
An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().